The CELLTREAT 229371 225cm2 Tissue Culture Flask provides a reliable vented cap that ensures optimal gas exchange while preserving sterility. Its large opening and canted neck design make cell scraping effortless, and the stable base allows upright filling without spills. Packaged in a zip closure bag, the case of 25 offers convenient storage and easy access for laboratory workflows.

9999 in stock
SKU: CJN2DKB01N7W Category:
Trust Badge Image

Description

Product Overview

The CELLTREAT 229371 225cm2 Tissue Culture Flask is engineered for demanding cell culture applications where sterility, gas exchange, and ease of handling are paramount. Constructed from high‑quality borosilicate glass, the flask offers excellent chemical resistance and thermal stability, allowing it to withstand autoclaving, UV sterilization, and a wide temperature range without compromising structural integrity. The vented cap incorporates a precision‑engineered filter that permits free diffusion of oxygen and carbon dioxide while maintaining a robust sterile barrier, eliminating the need for additional gas‑exchange devices.

Measuring 225cm2 of growth surface, the flask provides ample area for adherent cell lines, primary cultures, and suspension cultures. The canted neck design, combined with a large opening, facilitates effortless access for cell scrapers, pipettes, and media exchange, reducing the risk of contamination and minimizing cell loss during routine procedures. The stable, wide‑base geometry ensures that the flask can be filled and incubated upright, preventing spillage and enabling consistent positioning within standard incubators and shakers.

Each unit is supplied in a zip‑closure bag that protects the flask from dust and mechanical damage during storage and transport. The case contains 25 flasks, offering laboratories a cost‑effective solution for high‑throughput experiments, batch processing, and reproducible research workflows. Detailed product specifications, including dimensions, weight, and model number, are provided to assist with inventory management and compatibility checks.

Product front view showing all components

Usage

Designed for versatility, the CELLTREAT 229371 flask excels in a variety of laboratory settings, from academic research labs to industrial bioprocessing facilities. Its vented cap is ideal for cultures that require precise control of atmospheric gases, such as stem cell maintenance, viral production, and metabolic studies. The flask’s robust glass construction tolerates repeated media changes, sub‑culturing, and centrifugation steps, making it suitable for long‑term culture and high‑density cell growth.

When used in conjunction with standard laboratory equipment—such as orbital shakers, incubators, and laminar flow hoods—the flask integrates seamlessly into existing workflows. The large opening allows for rapid addition of reagents, while the canted neck reduces the likelihood of accidental spills during pipetting. Researchers can employ the flask for both adherent and suspension cell lines, benefiting from the uniform temperature distribution and efficient gas exchange provided by the vented cap.

For quality‑controlled environments, the zip‑closure bag ensures that each flask remains sterile until the moment of use, simplifying aseptic technique and reducing preparation time. The case of 25 flasks supports batch processing, enabling simultaneous setup of multiple experiments with consistent conditions across replicates.

Why Choose Us

Choosing CELLTREAT means partnering with a trusted manufacturer dedicated to scientific excellence. Our flasks undergo rigorous quality assurance testing, including leak testing of vent caps, verification of glass thickness, and validation of sterility after gamma irradiation. This commitment to quality ensures that every flask delivers reliable performance, minimizing experimental variability and protecting valuable research investments.

We understand the importance of reproducibility in cell culture, which is why our flasks are produced with tight tolerances on dimensions and surface area. The consistent 225cm2 growth area allows researchers to compare results across different batches and laboratories with confidence. Additionally, our customer support team provides technical assistance, troubleshooting guidance, and rapid response to any product‑related inquiries, reinforcing our dedication to user success.

Environmental responsibility is also a core value. The borosilicate glass used in our flasks is recyclable, and our packaging is designed to reduce waste while maintaining product integrity. By selecting CELLTREAT, laboratories benefit from a sustainable, high‑performance solution that aligns with both scientific and ecological goals.

Key Features

  • Vent cap with sterile filter enables optimal gas exchange without compromising sterility.
  • Large 225cm2 surface area supports high‑density cell growth and diverse culture types.
  • Canted neck and wide opening simplify media changes, cell scraping, and reagent addition.
  • Stable base design allows upright filling and secure placement in incubators and shakers.
  • Comes with zip‑closure bag and case of 25 for convenient storage, easy access, and cost‑effective bulk purchasing.

FAQ

What type of filter is used in the vent cap?

The vent cap incorporates a 0.2 µm PTFE membrane filter that blocks microorganisms while allowing free diffusion of gases, ensuring a sterile environment for cell culture.

Can the flask be autoclaved?

Yes, the borosilicate glass construction tolerates standard autoclave cycles (121 °C, 15 psi) without deformation or loss of integrity, making it suitable for repeated sterilization.

Is the flask compatible with standard incubator shelves?

The flask’s dimensions and stable base are designed to fit common incubator shelf sizes, allowing secure placement and consistent temperature exposure across multiple devices.

How should the zip‑closure bag be stored?

Store the zip‑closure bag in a cool, dry place away from direct sunlight. The bag protects the flask from dust and mechanical damage until the moment of use.

What support is available if I encounter an issue?

Our technical support team is available via email and phone to assist with any product‑related questions, troubleshooting, or replacement requests, ensuring minimal disruption to your research workflow.

Reviews

There are no reviews yet.

Be the first to review “CELLTREAT 229371 225cm2 Tissue Culture Flask with Vent Cap Pack of 25”

Your email address will not be published. Required fields are marked *

Recently Viewed Products

Shopping cart

2

Subtotal: $191.07

View cartCheckout